e-docs > Tuxedo > Messages > CMDTUX Catalog List > CMDTUX Messages 600-699 |
|
CMDTUX Messages 600-699
601
ERROR: Memory allocation failure for receive buffer
Description
An attempt to dynamically allocate memory from the operating system using malloc()
failed while allocating a buffer to receive network messages.
Action
Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
602
ERROR: Network access error
Description
There are two possible causes:
Action
603
ERROR: Memory allocation failure
Description
An attempt to dynamically allocate memory from the operating system using malloc()
failed while the tagent
was processing a request.
Action
Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
604
ERROR: Could not decode request message
Description
The tagent
process received an invalid request message that it could not decode.
Action
Verify that the correct release of the BEA TUXEDO system is running on both machines. The master machine can be at most one release ahead of other machines in the network.
Contact your BEA TUXEDO system Technical Support.
605
ERROR: Could not set uid/gid for request
Description
The tagent
process received a failure from the setgid()
or setuid()
kernel calls. This indicates that it is not running with the correct login user id or group id.
Action
The tlisten
process must be started with a UNIX user id and group id that matches the configuration file. Refer to the UID
and GID
parameters of the RESOURCES and MACHINES sections.
See Also
ubbconfig
(5)
606
ERROR: Invalid version number for request
Description
The tagent
process received a request from an incompatible version of the BEA TUXEDO system.
Action
Verify that the correct release of the BEA TUXEDO system is running on both machines. The master machine can be at most one release ahead of other machines in the network.
607
ERROR: Error encoding reply message
Description
A reply message from the tagent
process could not be encoded.
Action
Contact your BEA TUXEDO system Technical Support.
609
ERROR: Invalid arguments for opcode
Description
The tagent
process received a request message containing invalid argument values.
Action
Contact your BEA TUXEDO system Technical Support.
610
ERROR: Could not creat temp file for TUXCONFIG
Description
The tagent
process could not create or write a temporary file for propagation of the configuration file.
Action
Check the directory permissions and free disk space in the system's temporary file directory. The tagent
uses UNIX's tmpnam()
library function to obtain temporary file names.
611
ERROR: tmloadcf failed when creating new configuration file
Description
The tagent
process was attempting to load a new configuration file, and tmloadcf
failed.
Action
tmboot
output for any userlog or error messages.
$TUXDIR/bin/tmloadcf
exists and is executable.
TUXCONFIG
file name, directory permissions, and file permissions are set correctly.
TUXCONFIG
file already exists, try removing it and then running tmboot
again.
612
ERROR: Could not set environment variable
Description
The tagent
process encountered an error when attempting to set an environment variable using UNIX's putenv()
call.
Action
tlisten
was started.
613
ERROR: Could not retrieve parameters from TUXCONFIG file
Description
The tagent
process encountered an error when attempting to read an existing TUXCONFIG
file.
Action
Contact your BEA TUXEDO system Technical Support.
614
ERROR: Unknown error, terminating
Description
The tagent
process encountered an unknown error.
Action
Contact your BEA TUXEDO system Technical Support.
615
INFO: Terminating tlisten process
Description
The tlisten
process will print this message in the tlisten log file when terminating. The only valid exit for the tlisten
process is when it receives a SIGTERM
termination signal.
Action
No action required.
See Also
tlisten
(1)
617
ERROR: Invalid tlisten option option
Description
An invalid option, option, was passed to tlisten
.
Action
Select the appropriate option(s) from the usage line that follows the message.
See Also
tlisten
(1)
624
ERROR: tlisten network address not specified
Description
The user needs to pass the network address where the tlisten
process is to listen for connection requests. The address should be passed as an argument to the -l
option.
Action
Invoke tlisten
with the -l
nlsaddr option. The value passed as nlsaddr should be the same as that specified for the NLSADDR
parameter in the NETWORK section of the configuration file.
See Also
tlisten
(1), ubbconfig
(5)
626
ERROR: tlisten could not find entry for user username
Description
The user has the option to reset the user id and group id of the tlisten
process through the -u
option. If the user id or user name passed as an argument is invalid, the tlisten
process will print this message and terminate.
Action
Verify that the argument to the tlisten -u
option is a valid user id or user name.
See Also
tlisten
(1)
627
ERROR: tlisten cannot run as root
Description
The tlisten
process was most likely invoked by root
. For security purposes, this is not allowed.
Action
The user should use the -u
option to specify an alternate user id or user name instead of root
, or invoke the tlisten
process from another login.
See Also
tlisten
(1)
628
ERROR: tlisten could not set user id to user_name
Description
The tlisten
process failed to reset its user id.
Action
Verify that the user name or user id passed as an argument to the -u
option has a valid entry in the /etc/passwd
file.
See Also
tlisten
(1)
629
ERROR: tlisten invoked by non-root, can't change user id.
Description
The user id of the tlisten
process may only be changed if the tlisten process was originally invoked by root. When invoked by someone other than root, the user id of the tlisten
process may not be reset.
Action
If the user wishes to have the tlisten
process run with a specific user id, tlisten
should either be invoked by that user, or by root. When invoked by root, the -u
option should be used to reset the user id.
See Also
tlisten
(1)
636
WARN: Error sending acknowledgment back to requester
Description
The tlisten
process was unable to send an acknowledgment back to the requester. The problem associated with this error is not likely to be caused by something that the invoker of the tlisten
process will have done. Nor is it likely to be a BEA TUXEDO system error.
Action
Try repeating the same operation. If this fails with the same error, contact your UNIX System administrator or your BEA TUXEDO system Technical Support.
See Also
tlisten
(1)
642
ERROR: Invalid service request received, bad message header
Description
The DBBL
or BBL
process received an invalid service request message. It will be ignored.
Action
Contact your BEA TUXEDO system Technical Support.
644
ERROR: Cannot remove BRIDGE on machine machine
Description
The DBBL
process could not remove the bulletin board entry for machine's BRIDGE
process.
Action
Contact your BEA TUXEDO system Technical Support.
645
ERROR: Cannot unregister BBL on machine machine
Description
The DBBL
process could not remove the bulletin board entry for machine's BBL
process.
Action
Contact your BEA TUXEDO system Technical Support.
646
ERROR: Could not restore DBBL entry after temp change for shutdown
Description
The DBBL
's server table entry in the bulletin board had been temporarily modified to allow a partitioned shutdown. The original entry could not be restored.
Action
Contact your BEA TUXEDO system Technical Support.
647
ERROR: Failed to update status of restarting BRIDGE
Description
The local BRIDGE
process was marked in the bulletin board as restarting when a new bulletin board upload arrived. This status could not be restored after the upload request was processed.
Action
Contact your BEA TUXEDO system Technical Support.
648
ERROR: DBBL should not receive an O_MIGGRPS opcode
Description
The DBBL
process received an internal migration operation code intended for BBLs
only. The request will be ignored.
Action
Contact your BEA TUXEDO system Technical Support.
649
ERROR: BBL should not receive an O_UPDGRPS opcode
Description
A BBL
process received an internal operation code intended for DBBL
s only. The request will be ignored.
Action
Contact your BEA TUXEDO system Technical Support.
650
ERROR: Could not create message queue for temporary DBBL
Description
A temporary DBBL
was being created for partitioned shutdown. There was an error when creating its message queue.
Action
Contact your BEA TUXEDO system Technical Support.
651
ERROR: Could not update bulletin board for temporary DBBL
Description
A temporary DBBL
was being created for partitioned shutdown. There was an error when updating its server table entry in the bulletin board.
Action
Contact your BEA TUXEDO system Technical Support.
652
ERROR: Could not create message queue for DBBL migration
Description
The DBBL
process is migrating to this machine. However, a message queue could not be created for it.
Action
If after the migration the DBBL
process is not running on either the master or backup machine, try a partitioned shutdown and reboot of the master. If this does not solve the problem, contact your BEA TUXEDO system Technical Support.
See Also
tmboot
(1), tmshutdown
(1)
653
ERROR: Could not update DBBL server table entry for migration
Description
The DBBL
process is migrating to this machine. However, its new server table entry in the bulletin board could not be updated.
Action
If after this migration the DBBL
process is not running on either the master or backup machine, try a partitioned shutdown and reboot of the master. If the error persists, contact your BEA TUXEDO system Technical Support.
654
ERROR: Could not retrieve own bulletin board entry for migration
Description
The DBBL
process is migrating to another machine. However, it could not find its own server table entry in the bulletin board. This prevents the old DBBL
from broadcasting where the new DBBL is located.
Action
After this migration it is possible that a DBBL
process is running on both the master or backup machines. If so, shut down the machine with the newest one (that is, the destination of the last migrate command). Then boot that machine up and try to migrate again. If the error persists, contact your BEA TUXEDO system Technical Support.
See Also
tmboot
(1), tmshutdown
(1)
655
INFO: Exiting system for migration from mach1 to mach2
Description
The DBBL
process has migrated to another machine. The old DBBL
outputs this message just before exiting.
Action
No action required.
See Also
tmadmin
(1) migrate
command
656
ERROR: DBBL should not receive an O_WARMSTART opcode
Description
The DBBL
process received an internal operation code intended for BBL
s only. The request will be ignored.
Action
Contact your BEA TUXEDO system Technical Support.
657
ERROR: DBBL should not receive an O_LOADTLOG opcode
Description
The DBBL
process received an internal operation code intended for BBL
s only. The request will be ignored.
Action
Contact your BEA TUXEDO system Technical Support.
662
ERROR: Incompatible TLOG file
Description
The data file being loaded into the TLOG assumes a different maximum number of groups involved per transaction than this BEA TUXEDO system software release allows.
Action
Contact your BEA TUXEDO system Technical Support.
663
INFO: Exiting system
Description
A temporary DBBL
that was running to facilitate partitioned shutdown is now exiting.
Action
No action required.
664
ERROR: Service request from process pid failed
Description
A serious failure occurred when processing a service request, and an error response message could not be returned to the originator. Possible causes of the error are: memory allocation failure, software version mismatch, or a shutdown is in progress.
pid is the UNIX System process id number of the requester. However, it might be located on a remote machine.
Action
Contact your BEA TUXEDO system Technical Support.
665
ERROR: Could not unsuspend reconnected node nodename
Description
nodename is a remote machine that had been previously partitioned. It is now back and reconnected to the DBBL
. There was a problem unsuspending nodename's services while accepting it back into the network. It will remain partitioned.
Action
On the master machine, perform a tmadmin pclean
command for the partitioned node. On the partitioned machine, do a partitioned shutdown and then reboot.
See Also
tmadmin
(1), pclean
command, tmshutdown
(1), tmboot
(1)
668
WARN: Stale message received from BBL on machine machinename
Description
During collection of responses to a DBBL
broadcast, a stale message (from a previous broadcast) was received from machinename's BBL. The stale message will be ignored.
Action
Check the status of machinename, and its network connections.
669
WARN: Stray string received from process pid
Description
During collection of responses to a DBBL
broadcast, an ACK or NACK message was received from an unrecognized process. The ACK/NACK message will be ignored.
Action
No action required.
670
ERROR: Cannot restore message queue, key queuekey
Description
If the DBBL
's UNIX System message queue is ever removed, the DBBL
will attempt to recreate it. This should never happen, but the DBBL
has recovery code for extra reliability.
This error means the message queue recovery code itself failed. It is a serious error because the DBBL
cannot function without a message queue.
Action
Use the UNIX System kill
command to force a DBBL
restart. If it does not restart successfully within a few minutes, contact your BEA TUXEDO system Technical Support.
See Also
kill
(1) in UNIX System reference manuals
672
INFO: Sending BBL on machine name new version of bulletin board
Description
The BBL
on machine name is being sent a new copy of the bulletin board by the DBBL
. This would occur if a previous bulletin board update request failed, or if machine name had been partitioned and now is reconnected.
Action
No action required.
680
ERROR: Cannot find own table entry
Description
If the DBBL
's UNIX System message queue is ever removed, the DBBL
will attempt to recreate it. This should never happen, but the DBBL
has recovery code for extra reliability.
This error means the message queue recovery code itself failed. It is a serious error because the DBBL
cannot function without a message queue.
Action
Use the UNIX System kill
command to force a DBBL
restart.
If it does not restart successfully within a few minutes, contact your BEA TUXEDO system Technical Support.
681
ERROR: Cannot update own table entry
Description
If the DBBL
's UNIX System message queue is ever removed, the DBBL
will attempt to recreate it. This should never happen, but the DBBL
has recovery code for extra reliability.
This error means the message queue recovery code itself failed. It is a serious error because the DBBL
cannot function without a message queue.
Action
Use the UNIX System kill
command to force a DBBL
restart.
If it does not restart successfully within a few minutes, contact your BEA TUXEDO system Technical Support.
682
WARN: New message queue created, key =number
Description
If the DBBL
's UNIX System message queue is ever removed, the DBBL
will attempt to recreate it. This should never happen, but the DBBL
has recovery code for extra reliability.
This message is output after the DBBL
successfully recreates its queue.
Action
No action required.
683
ERROR: Group id for migration is missing
Description
One or more server groups could not be migrated because an internal system message is missing necessary data.
Action
Contact your BEA TUXEDO system Technical Support.
684
ERROR: Memory allocation error
Description
An attempt to dynamically allocate memory from the operating system using malloc()
failed while migrating one or more groups.
Action
Ensure that the operating system parameters are set correctly for the amount of memory on the machine and the amount of memory that can be used by a process. Reduce the memory usage on the machine or increase the amount of physical memory on the machine.
685
ERROR: Could not retrieve server entries for migration
Description
One or more server groups could not be migrated because server table entries in the bulletin board could not be retrieved.
Action
Contact your BEA TUXEDO system Technical Support.
686
ERROR: Could not update migrating server's status
Description
A migrating server's status could not be updated in the bulletin board.
Action
Contact your BEA TUXEDO system Technical Support.
687
INFO: Server process marked for migration restart, srvgrp=number srvid=number
Description
The server process has been migrated, and is about to be restarted on the current machine.
Action
No action required.
See Also
tmadmin
(1), migrategroup
and migratemach
commands
688
ERROR: Running server cannot be migrated, srvgrp=number srvid=number
Description
A request was made to migrate this server process. The migration could not proceed because it is still running.
Action
Shut down the process using tmshutdown
's -R
option before migrating it.
See Also
tmadmin
(1), migrategroup
and migratemach
commands
692
ERROR: Cannot retrieve BBL entry for pclean operation
Description
When attempting to clean up after a dead or partitioned machine, the DBBL
could not find any record of that machine's BBL
process.
Action
Contact your BEA TUXEDO system Technical Support.
See Also
tmadmin
(1), pclean
command
694
ERROR: Cannot lock bulletin board for pclean operation
Description
A bulletin board lock could not be obtained when attempting to clean up after a dead or partitioned machine.
Action
Try again after a few seconds, giving the bulletin board lock recovery algorithm time to run. If this error continues, contact your BEA TUXEDO system Technical Support.
See Also
tmadmin
(1), pclean
command
695
ERROR: Could not remove server entry for tmid number
Description
When attempting to clean up after a dead or partitioned machine, a server table entry could not be removed from the bulletin board.
Action
Contact your BEA TUXEDO system Technical Support.
See Also
tmadmin
(1), pclean
command
697
ERROR: Could not access *RESOURCES section of TUXCONFIG file
Description
When attempting to update the version number of the master copy TUXCONFIG
file, the RESOURCES section could not be read.
Action
Apparently something has happened to the master machine's TUXCONFIG
file. It can be restored by shutting down the entire application, and then running tmloadcf
on a backup ASCII copy. Running tmunloadcf
on a different machine's TUXCONFIG
file should provide a recent backup version.
See Also
tmloadcf
(1), tmunloadcf
(1)
698
ERROR: Could not read *RESOURCES section of TUXCONFIG file
Description
When attempting to update the version number of the master copy of the TUXCONFIG
file, the RESOURCES section could not be read.
Action
Apparently something has happened to the master machine's TUXCONFIG
file. It can be restored by shutting down the entire application, and then running tmloadcf
on a backup ASCII version. Running tmunloadcf
on a different machine's TUXCONFIG
file should provide a recent backup version.
See Also
tmloadcf
(1), tmunloadcf
(1)
699
ERROR: Could not update *GROUPS section of TUXCONFIG file
Description
The location of a server group was being updated in the master copy of the TUXCONFIG
file, to reflect a new location after migration. An error prevented the GROUPS section from being read (or updated).
Action
Apparently something has happened to the master machine's TUXCONFIG
file. It can be restored by shutting down the entire application, and then running tmloadcf
on a backup ASCII version. Running tmunloadcf
on a different machine's TUXCONFIG
file should provide a recent backup version.
See Also
tmloadcf
(1), tmunloadcf
(1)
![]() |
![]() |
![]() |
![]() |
||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |