1100 |
ERROR: Unable to find TP_CRL_ROUTING_UPDATE record | |
|
Description |
Message received from the BEA TOP END system indicated that a routing update message was sent along with the received message. However, the attempt to retrieve the routing data failed. The received message was malformed and was dropped. |
Action |
Contact your BEA TUXEDO System Customer Support. | |
1101 |
ERROR: Unexpected dialogue request type | |
|
Description |
A malformed message was received from the BEA TOP END system. The message was dropped. |
Action |
Contact your BEA TUXEDO System Customer Support. | |
1102 |
ERROR: Unexpected signon message received | |
|
Description |
Signon message received for a dialog that was already in conversation. Dialog reset was sent to the BEA TOP END system. |
Action |
Contact your BEA TUXEDO System Customer Support. | |
1103 |
INFO: Service request received without intervening response | |
|
Description |
Two sequential service requests were received without an intervening response for a dialog that was in conversational mode. The subsequent service request was dropped. |
Action |
No action required. | |
1104 |
ERROR: Unable to obtain remote domain id (domainid) information from shared memory | |
|
Description |
While receiving data, shared memory information for the specified remote domain domainid is not available. |
Action |
Check the configuration for proper listing of the specified remote domain. | |
See Also |
| |
1105 |
INFO: BEA TOP END request received with attachment info, ignoring attachment info | |
|
Description |
A BEA TOP END application was attempting to send a message with Large Message Architecture (LMA) attachment data. However, the TOP END Domain Gateway does not support LMA. The attachment information was dropped. |
Action |
Modify the BEA TOP END application to eliminate use of the LMA feature. | |
See Also |
BEA TOP END Application Programmer's Guide | |
1107 |
ERROR: Unable to find local service in shared memory | |
|
Description |
Shared memory information for the local service was not available. Severe shared memory error. |
Action |
Contact your BEA TUXEDO System Customer Support. | |
1108 |
ERROR: TP_APPL_CONTEXT flag set for non-conversational service | |
|
Description |
A BEA TOP END client application had the |
Action |
If conversational behavior is desired, modify the | |
See Also |
| |
1109 |
ERROR: Invalid buffer type | |
|
Description |
The incoming BEA TOP END message was in FML32 format. However, the expected incoming buffer type was not specified as FML32. The request was dropped. |
Action |
Modify the local service entry in the | |
See Also |
| |
1110 |
ERROR: Unable to find remote service in shared memory | |
|
Description |
Shared memory information for the remote service was not available. Severe shared memory error. |
Action |
Contact your BEA TUXEDO System Customer Support. | |
1111 |
ERROR: FML decode error | |
|
Description |
The decoding of FML32 formatted user data for an incoming BEA TOP END message failed. The likely cause was data corruption. The dialog with the BEA TOP END system was reset. |
Action |
Contact your BEA TUXEDO System Customer Support. | |
1112 |
ERROR: Unexpected disconnect message received | |
|
Description |
A disconnect message was received from the BEA TOP END system for an unknown conversation. This message may have been received following conversation cleanup as a result of a disconnect initiated by the TOP END Domain Gateway. Alternatively, this message may have been received in error. |
Action |
Contact your BEA TUXEDO System Customer Support. |
|